MERX-M Metylmercury System for EPA 1630

MERX-M Automated Mercury Systems is the world’s first commercial automated analytical system based on US EPA Method 1630 for methylmercury analysis. Around the world, numerous national environmental agencies and leading university have quickly embraced MERX as an easy-to-use, robust, and reliable system that delivers high quality data.

Methylmercury Methodology

Sample Preparation

Prior to analysis, samples are prepared as per normal methylmercury methodology, typically distillation for water (US EPA 1630), extraction for sediment or digestion for tissue.

Vial Loading

Prepared samples are added to 40 mL vials with Teflon® lined septa caps. Samples are buffered to pH 4.9, ethylated with the addition of NaBEt4, topped off with DI water, capped, shaken and loaded into the autosampler.

Software Setup

Sample information is entered into Mercury Guru™ software, settings are selected and then sample analysis begins. MERX does the rest!

Liquid Handling

As each vial is pierced, the liquid is automatically transferred via gas pressure to a purge vessel where N2 gas volatilizes ethylated Hg species to a Tenax® trap.

Trap Processing

The first trap is dried while another trap collects ethylated Hg species from the next vial. After drying, another vial is purged onto a third trap while the second is dried, and the first trap, now dry, is ballistically heated to thermally release the Hg species in an argon carrier gas stream.

GC Separation

The released Hg species are separated on a GC column and then thermally reduced to elemental mercury.

CVAFS Detection

Mercury is detected using the Brooks Rand Model III cold vapor atomic fluorescence spectrophotometer (CVAFS) with patented optics for enhanced sensitivity.

Data Processing

Mercury Guru™ software integrates the detector signal and calculates results based on calibration and sample volume information. QC results are automatically flagged based on user defined criteria.

System includes the following modules: MERX Autosampler, MERX Methyl HgGC& Pyrolysis Module, MERX Methyl Hg Purge & Trap Module, Model III CVASF Detector. Click here to purchase modules separately.

Key Features

    • Ultra-Low Level: All MERX system undergoes rigorous QC testing to ensure they achieve an instrument detection limit of <0.002 ng/L
    • Quantifiable range of 5000x (0.005ng/L – 25 ng/L) providing a wide linear range
    • Reduced carryover contamination – With the patent pending gas-pressurized liquid handling system, the purge gas not only transfers the ethylated sample to the purge vessel, but also continues to flow through the sample vial and transfer line to remove any residual volatile mercury compounds, thus allowing the next sample to be processed immediately without a rinse cycle.
    • Sharper peaks – The patent pending ballistic trap heating releases the ethylated mercury species instantly, resulting in sharper peaks and improved GC separation.
    • Fast – MERX utilizes a multiple trap configuration, such that all three traps are in use simultaneously at different stages in the analytical process, resulting in runs every 6.5 minutes or less.
  • Less maintenance – With the pump-free MERX system, there is no pump maintenance or constant requirements for tubing replacement. MERX has only a few replacement parts, which are all easily accessible and designed for longevity. Trap sets average over 4000 runs and most other replacement parts last much longer.
Filter
Item No. Alt. Part No. Product Description Unit of Measure Your Cost Purchase
MERXM METHYLMERC SYS *DS*
BRI5000-04400
EF44190 MERX-M Automated Methylmercury System for US EPA Method 1630 (115V) Each
$43,050.95
Add to Cart This item is not currently stocked. Allow 1-2 weeks. Please call us at 800-328-8378 if you'd like us to keep stock in the future In Stock
MERXM METHYHG SYS 230V *DS*
BRI5000-24400
EF44252 MERX-M Automated Methylmercury System for US EPA Method 1630 (230V) Each
$43,050.95
Add to Cart This item is not currently stocked. Allow 1-2 weeks. Please call us at 800-328-8378 if you'd like us to keep stock in the future In Stock