Methylmercury Manual System for EPA 1630
The Brooks Rand Methylmercury Manual System for EPA 1630 is specifically designed for methylmercury analysis by EPA Method 1630.
The standard Brooks Rand methylmercury system combines easy-to-use automated analysis with manual purge and trap for a high throughput, cost-effective system. This system consists of the Model III, the Trap Desorption Module and the GC and Pyrolysis Module for automated trap analysis, along with the manual Methyl Hg Purge and Trap Module. This semi-automated system allows for the simultaneous purging of multiple samples while previously loaded traps are analyzed. The result is a throughput rate of less than 8 minutes per sample. All systems come complete with the Brooks Rand Guru™ Software for system control and peak integration.
System includes the following modules: MERX Autosampler, MERX Total Hg Purge & Trap Module, Model III CVASF Detector. Click here to purchase modules separately.
Trap Desorption Module
SIMPLE OPERATION – Automates analysis from trap with a single keystroke from Guru™ Software.
CONSISTENCY – Provides simultaneous heating and integration resulting in consistent retention times.
Applications | For monomethyl and dimethyl mercury analysis of prepared water samples (by EPA Method 1630), sediment/soil samples or biological samples.
Description | Controls heating of methylmercury trap and carrier gas flow through the trap, the GC and Pyrolysis Module, and the Model III detector.
GC and Pyrolysis Module
CONSISTENCY – The tightly regulated temperature of the GC oven results in consistent retention times and excellent precision.
FLEXIBILITY – Programmable temperature of the GC oven provides analyst flexibility for improved peak separation or faster run times.
Applications | For monomethyl and dimethyl mercury analysis of prepared water samples (by EPA Method 1630), sediment/soil samples or biological samples.
Description |Controls heating of methylmercury trap and carrier gas flow through the trap, the GC and Pyrolysis Module, and the Model III detector.
Methyl Hg Purge and Trap Module
VERSATILE – Purge and trap modules are available in a variety of sizes to match your throughput needs and budget.
ANALYST CONTROL – The manual purge and trap module allows ultimate flexibility for the analyst. Sample-specific volumes and dilutions can be carried out to reduce the risks of overloading the system with mercury and to minimize reruns.
Applications | For monomethyl and dimethyl mercury analysis of prepared water samples (by EPA Method 1630), sediment/soil samples or biological samples.
Description | Performs the ethylation, volatilization, and trapping of prepared liquid samples and controls the purge gas flow rate.
Item No. | Alt. Part No. | Product Description | Unit of Measure | Your Cost | Purchase |
---|---|---|---|---|---|
METHYHG SYS EPA1630 230V *DS*
BRI5000-24010
|
EF44251 | Methylmercury System for EPA 1630 - Manual (230V) | Each |
$26,150.95
|
|
METHYLMERC SYS EPA1360 *DS*
BRI5000-04010
|
EF44189 | Methylmercury System for EPA 1630 - Manual (115V) | Each |
$26,150.95
|