Thermo Orion Pro Star EC212 Conductivity Benchtop Meter

The Thermo Orion Pro Star EC212 Conductivity Benchtop Meter is designed to provide accurate, reliable electrochemistry testing. Featuring an intuitive interface, enhanced data reporting and robust functionality, the Orion Pro Star EC212 meter delivers advanced performance in a modern and simplified package.

The Orion Pro Star EC212 meter features a wide range of parameter capabilities, including conductivity, TDS, salinity or resistivity with temperature.

As with all Orion Pro Star Meters, the EC212 meter features:

  • Large 7-inch, high-resolution color display
  • Responsive capacitive touchscreen operable with gloves
  • Angled display to help ensure ergonomic viewing
  • Streamlined, easy to operate user interface
  • Vertical meter orientation helps optimize bench space
  • Supports GLP compliance
  • Stores 20 calibration logs per parameter with date and time
  • Stores 10,000 data log sets with date and time
  • Outputs to a printer, computer, or USB flash drive for long-term data retention
  • Inputs sample ID with optional USB barcode scanner, USB keyboard, or USB mouse
  • Meter-controlled and meter-powered stirrer probe

Choose from a variety of package options:

Meter Only: Benchtop Meter with electrode stand, USB flash drive, computer cable, 100-240V 50/60Hz universal power adapter (purchase electrodes separately)

Standard Kit: Benchtop Meter with stand (PSTAR2120), 4-cell epoxy/graphite-body K=0.475 conductivity/ATC electrode (013005MD), 1413µS/cm conductivity standard pouches

Pure Water Kit: Benchtop Meter with stand (PSTAR2120), ultra pure water 2-cell K=0.1 conductivity/ATC electrode with flow cell (013016MD), 100µS/cm conductivity standard bottles


Specifications on the Orion Pro Star EC212 Benchtop Meter
Conductivity
Range 0.010 μS/cm to 3000 mS/cm
Resolution 0.001 μS/cm minimum, auto-ranging, up to 4 digits
Relative Accuracy ±0.5% reading
Calibration Points 1 to 5 points
Calibration Method Automatic standard recognition, manual entry option
Calibration Standards 100.0 μS/cm, 1413 μS/cm, 12.88 mS/cm, 111.9 mS/cm or up to 4 custom standards
Nominal Cell Constant 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or
user-defined from 0.001 to 199.9 cm-1
Temperature Compensation Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off
Reference Temperature 5, 10, 15, 20, 25 or 30°C
TDS
Range 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or
0.010 mg/L to 500.0 g/L (TDS factor of 1.00)
Resolution 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits
Relative Accuracy ±0.5% reading
Units ppm to ppt; or mg/L to g/L
Calibration Point 1 to 5 points
TDS Factor Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl
Salinity
Range 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl
Resolution 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging
Relative Accuracy ±0.5% reading
Calibration Points 1 point % NaCl
Modes Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl
Resistivity
Range 1.0 Ω to 100.0 MΩ
Resolution 0.1 Ω minimum, auto-ranging
Relative Accuracy ±0.5% reading
Temperature
Range –30.0 to 130.0ºC, –22.0 to 266.0ºF
Resolution 0.1ºC, 0.1 ºF
Relative Accuracy ±0.3ºC, ±0.5ºF
Calibration Points 1 or 2 points
Offset Adjustment Up to ±5.0ºC
Temperature Source Automatic with ATC sensor, ambient with built-in meter temperature sensor or manual entry
Measurement   Functions
Measurement Channels 1
Measurement Parameters Conductivity, TDS, salinity or resistivity with temperature
Read Types Continuous, Auto-Read or Timed
Timed Reading Intervals 3 seconds to 2 hours
Measurement Layout Customizable options for basic, advanced or user-defined
Measurement Stability Automatic, fast, medium or slow
Sample ID Auto-incremental or manual, up to 25 alphanumeric characters
Electrode ID Up to 20 alphanumeric characters
Graph/Chart View Single parameter with temperature
Set Value Alarm 1 high and 1 low value per parameter
Last Calibration Details Calibration summary with date and time


EC212   Meter Features
Display 7-inch, high-resolution color graphic LCD
Touchscreen Type Capacitive with lab glove compatibility
Onscreen Prompts On-demand information screens; onscreen user guide and step-by-step calibration guidance
Time And Date Yes
Time Format 12 or 24 hour
Date Format Selectable as MM-DD-YYYY, DD-MM-YYYY or DD-MMM-YYYY
Instrument Name Up to 20 alphanumeric characters
Secure Mode 3 administrator and 30 user accounts with individual password protection,
custom user access permissions and audit trail
Username Up to 20 alphanumeric characters
Methods 10
Data Outputs USB flash drive, computer or compact ink printer
Data Output Format Report, CSV or print
Data Log 10,000 data sets with time and date
Data Log Export Customizable options for basic (short), intermediate, advanced or all data
Calibration Log 20 per parameter with time and date
Calibration Log Export Customizable options for basic (short), intermediate, advanced or all data
Calibration Reminder 1 alarm per parameter
Calibration Alarm Interval 1 hour to 30 days or off
Audible Signal User set for notifications and alarms, stable reading
Maintenance Reminder Up to 5 electrode maintenance reminders and up to 5 solution maintenance reminders
Sleep Mode Selectable time interval of 5, 10, 20, 30, 60 minutes or off
Meter Tests Self-test, stability test
Meter Tours And Guides Calibration modes, measurement mode, meter connections, electrode stand assembly
Stirrer Probe Inputs 1
Stirrer Probe Speeds 5 selectable speeds: from 250 RPM to 3600 RPM
Electrode Inputs 8-pin MiniDIN
Data Outputs 1 USB-A port for USB flash drive; 1 export port for computer or compact ink printer
Accessory Input 1 USB-A port for USB mouse, USB keyboard or USB barcode scanner
Memory Non-volatile, to preserve data and settings in case of power loss
Display Languages Chinese, English, French, German, Italian, Japanese, Korean, Portuguese or Spanish
Meter Warrany 2 years
Certifications CE, TUV 3-1, FCC Class A
Enclosure IP-54
Power 100-240 VAC, 50-60Hz, 9 DC adapter, 2.0A
Dimensions (L x W x H) 8.52 x 6.03 x 3.60 in.
Weight 2.20 lbs.
Filter
Item No. Alternative For Product Description Unit of Measure Your Cost Purchase
EC212 CONDUCTIVITY METER ONLY
8124-01
ORISTARA2120 Orion Pro Star EC212 Conductivity Benchtop Meter - Meter Only Each
$1,317.33
Add to Cart Please allow 5-10 business days. Call us at 800-328-8378 with any questions about availability. In Stock
EC212 COND. METER STANDARD KIT
8124-02
ORISTARA2125 Orion Pro Star EC212 Conductivity Benchtop Meter - Standard Kit Each
$1,763.67
Add to Cart Please allow 5-10 business days. Call us at 800-328-8378 with any questions about availability. In Stock
EC212 COND. METER PURE H2O KIT
8124-03
ORISTARA2126 Orion Pro Star EC212 Conductivity Benchtop Meter - Pure Water Kit Each
$1,852.93
Add to Cart Please allow 5-10 business days. Call us at 800-328-8378 with any questions about availability. In Stock