Thermo Scientific Orion Lab Star DO Dissolved Oxygen Bench Meter
The Thermo Scientific™ Orion™ Lab Star DO113 Dissolved Oxygen Bench Meter is ideally suited for laboratories with users of varying levels of technical expertise and who require a simple-to-calibrate and use meter for routine dissolved oxygen testing.
Measure dissolved oxygen as percent saturation, concentration in mg/L or concentration in ppm simultaneously with temperature using the Orion Lab Star DO113 DO Bench Meter. To enable comprehensive measurement capabilities, measure dissolved oxygen in a range of 0.0 to 300.0 % saturation, 0.00 to 30.0 mg/L or ppm and measure temperature in a range of -5.0 to 105.0°C or 23.0 to 221.0°F.
For proficient SOP compliance, perform 100% saturation, 0% saturation and custom concentration calibration for dissolved and one-point temperature adjustment calibrations.
Featuring a large, backlit display for easy viewability and small footprint to save bench space, this dissolved oxygen meter is ideally suited for simplified, budget-friendly lab testing. Use the onscreen stabilizing and ready indicators to help identify when DO meter readings are complete. View dissolved oxygen and temperature calibration logs with date and time stamp to ensure accurate, reproducible measurements. Record key measurements using the 500-point data log with date and time stamp. Output data logs and calibration logs to a printer or computer for long-term data storage.
Click here for a list of available accessories for the Thermo Scientific™ Orion™ Lab Star DO113 Dissolved Oxygen Bench Meter
Key Features
- Budget-friendly meter for simplified dissolved oxygen testing
- Large 5” backlit display makes viewing measurements easy
- Small meter footprint saves valuable lab bench space
- Date and time stamped logs support GLP compliance
- View active calibration logs with date and time to help ensure accuracy
- 500-point data log with date and time to track critical measurements
- Output data and calibration logs to a printer of computer for long-term data storage
- Stabilizing and ready indicators identify when measurements are complete
- Large primary dissolved oxygen measurement shown simultaneously with temperature measurements
- Durable membrane keypad to support rugged lab use and disinfection needs
- IP-54 rated housing protects meter against spills, splashes, and dust intrusion
- Twist-and-lock power adapter keeps power supply securely attached to meter
Specifications for Thermo Scientific Orion Lab Star Conductivity Bench Meter | |
---|---|
Parameter | Description |
Dissolved Oxygen as Percent Saturation | |
Range | 0.0 to 300.0 % saturation |
Resolution | 0.1, 1 % saturation |
Relative Accuracy | ±2 % saturation ± LSD |
Calibration Types | 100% and 0% |
Barometric Pressure Compensation | 400.0 to 850.0 mmHg; 0.533 to 1.133 bar |
Salinity Compensation | 0.0 to 50.0 ppt |
Dissolved Oxygen as Concentration | |
Units | mg/L or ppm |
Range | 0.00 to 30.0 mg/L or ppm |
Resolution | 0.01, 0.1 mg/L or ppmj |
Relative Accuracy | ±0.02 mg/L or ppm ± 1 LSD |
Calibration Points | 1 point, custom value |
Barometric Pressure Compensation | 400.0 to 850.0 mmHg; 0.533 to 1.133 bar |
Salinity Compensation | 0.0 to 50.0 ppt |
Temperature | |
Range | -5.0 to 105.0°C, 23.0 to 221.0°F |
Resolution | 0.1°C, 0.1°F |
Relative Accuracy | ±0.2°C, ±0.5°F |
Calibration Points | 1 point, custom value |
Offset Adjustment | Up to ±5°C |
Features | |
Display | 5" backlit LCD |
Time and Date | Yes |
Time Format | 12 hour AM/PM or 24 hour |
Date Format | Selectable, DD-MM-YYYY or MM-DD-YYYY |
Read Types | Continuous, Auto-Read, Timed |
Timed Interval | 5 seconds to 60 minutes |
Data Log | 500 sets with time and date |
Calibration Log | Active dissolved oxygen, temperature with time and date |
Calibration Alarm | Yes, 1 to 168 hours or off |
Sleep Mode | Yes, optional |
Self-Test | Automatic with startup |
Memory | Non-volatile |
Input | 9-pin MiniDIN |
Data Output | Computer or printer |
Data Output Format | CSV or print |
Warranty | 3-Years |
Certifications | CE, cTUVus, FCC Class B, CES-001, KC, RCM |
Enclosure | IP-54 |
Power | 100-240 VAC, 50-60 Hz, 9 DC adapter, 1.3A |
LxWxH | 7.37” x 6.11” x 2.43” |
Weight | 1.54 lbs |
Environmental Conditions | |
Environmental Conditions | Indoors |
Altitude | Up to 2,000 Meters |
Operating Temperature | 5°C to 45°C |
Operating Relative Humidity | 5 to 85%, non-condensing |
Storage Temperature | -20°C to 60°C |
Storage Relative Humidity | 5 to 85%, non-condensing |
Mains Fluctuation | ±10% of range (100-240VAC) |
Installation Category | II |
Pollution Degree | 2 |
Protection Class | III |
Item No. | Alt. Part No. | Product Description | Includes | Unit of Measure | Your Cost | Purchase |
---|---|---|---|---|---|---|
LAB STAR DO113 METER KIT
ORILSTAR1135
|
EF44784 | DO113 DO Bench Meter Standard Kit | Meter, electrode stand, PC cable, power adapter, 083005MD polarographic DO/ATC probe, 080513 DO probe kit, 080360 BOD adapter | Each |
$1,327.86
|
|
LAB STAR DO113 METER AND STAND
ORILSTAR1130
|
EF44783 | DO113 DO Bench Meter and Stand | Meter with electrode stand, PC cable, and universal power adapter | Each |
$843.14
|